Abstract
An experimental procedure is conducted to investigate the mechanism of the non-monotonic characteristic between curing temperature and mechanical behaviors of the Kevlar/epoxy composite in macro and micro levels. Different specimens are fabricated at four different curing temperatures and tested with ±45° off-axis tensile loading on a universal test machine coupled with digital image correlation (DIC). Moreover, the environmental scanning electron microscope (SEM) was used to obtain the micrographs and reveal their mechanism. The tested results show that the tensile mechanical behaviors are sensitive to the curing temperature and the relationship is non-monotonic. Also, as the temperature increases, the thicknesses of the specimens are significantly enlarged. By analyzing the SEM micrographs of the matrix grooves in the damage zone and DIC strain contours, it is concluded that the non-monotonic relationship is dominated by the properties of the Kevlar/epoxy interfaces and deformation of the distorted fibers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.