Abstract

The inorganic polymer concrete is a new environmentally material. Using the temperature - stress test machine to research its early cracking sensitivity, and compare it with the normal concrete. The deformation development process of inorganic polymer concrete consists three stages:early contraction, expansion, contraction to cracking; cracking temperature can effectively evaluate the overall cracking performance of concrete; the cracking temperature of inorganic polymer concrete is 14.2 °C, the normal concrete is 14.4 °C; the inorganic polymer concretes cracking stress is 2.658MPa, the normal concrete is 0.582MPa. The results show the inorganic polymers cracking performance is better than the normal concrete.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.