Abstract

The paper proposes a method to handle the challenge of temperature control in a closed-loop heat pump dryer that can operate both in heating cycle and refrigeration cycle. It is hard to avoid the violent fluctuations of drying temperature as the operation mode changes. Hence, the parallel conversion control is introduced to realize the accurate control of drying temperature. The main idea of the controller design lies in the use of different membership functions and fuzzy control rules for the two operation modes. Experimental results show that the temperature fluctuations are reduced when using parallel conversion control with fast and stable response as compared to the fixed-frequency and PID control system. One of the parameters, R f , representing the value of undershoot ratio is 0.4, 0.48, and 0.64 when drying temperature is fixed at 30, 35, and 38°C, respectively, with a parallel conversion controller. In order to study the application prospects of the parallel conversion control system, a comparison experiment with different compressor frequency ranges was also conducted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.