Abstract

Because of high temperature above 1000°C on fire, and Oxidation of carbon fiber at high temperature, fireproofing measure should be make to take advantage of the inorganic adhesive for beams strengthened by carbon fiber sheet bonded with the adhesive. The problem of which fireproofing material should be choose and how to make fireproofing measure needs to resolve. Fireproofing test is make for beams strengthened by carbon fiber sheet bonded with the adhesive protected by Thick-typed Fireproof Coating for steel structure (TFCSS) and Thick-typed Fireproof Coating for tunnel (TFCT). Typical damage state of the two typical coating is compared on and after fire, Temperature field of specimen is analyzed, and fireproofing effect is compared. The test results indicate that, under the protection of fireproof coating with proper structure, TFCT and TFCSS can supply effective fireproofing protection for carbon fiber sheet, but the former is inferior to the latter because the latter is easier to drop and crack in fire

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.