Abstract

The paper presented testing of surface defects by pulse video thermography techniques. Such techniques rely on transient infrared radiation from the sample heated by the short duration flux initiated by flesh. Experimental measurements are realized by infrared sensor (FLIR camera). Testing results are considered for the samples with controlled designed defects beyond observed surfaces. The effects of response through the transparent wall are measured as infrared visible radiance. Researches with controlled samples are performed to verify visibility threshold of defect dimensions and forms, for possible use as modulation transfer function of defects hidden beyond the surfaces of thin metal walls. Dimensionless coefficients are derived for method estimations as the results from experimental research.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.