Abstract

AbstractIn this paper, based on the analog theory of heat transfer research, we performed an analog experiment on boiling heat transfer in smooth tube and screwed tubes. These are widely used in the high pressure generator of lithium bromide absorption refrigeration. From the experimental research, we obtained a series of results on the boiling heat transfer of a single smooth tube and three screwed tubes. The working condition is near the zone of bubble boiling and the overheat wall temperature ranges from 2–7 °C, with a fluid medium of pure water and salt water solution. These results agreed well with the known results, and are significant for the practical design and application of a high pressure generator of lithium bromide absorption for refrigeration. © 2007 Wiley Periodicals, Inc. Heat Trans Asian Res, 36(2): 74–84, 2007; Published online in Wiley InterScience (www.interscience. wiley.com). DOI 10.1002/htj.20145

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.