The effect of whirl frequency and lubricant viscosity on the dynamic pressures and force response of an open end and a partially sealed squeeze film dampers (SFD) with a radial clearance of 0.38 mm is determined experimentally. The experiments are carried out in a damper test rig executing circular centered orbits and for whirl frequencies ranging from 33 to 83 Hz. The experimental results show that the sealed SFD configuration produces larger tangential forces than the open end SFD. The tangential (damping) force increases linearly with increasing whirl frequency. For this radial clearance fluid inertia effects in the damper are found to be negligible since the squeeze film Reynolds number is less than 1.20. Cavitation was observed in both damper configurations at high frequencies and high lubricant viscosities. This condition limited the rate of increment of the damping (tangential) force with increasing frequency and reduced the radial force when lubricant viscosity increased.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.