Abstract
This paper presents the experimental performance of a curved nozzle two-phase reaction turbine design for trilateral flash cycle heat engine. Results from two tests have been presented, for first test the average feed water temperature was maintained around 97 °C under local atmospheric pressure, while for the second test the average feed water temperature was maintained around 115 °C under 200 kPa absolute pressure. For both the tests the initial condenser pressure was maintained around 6 kPa absolute. The maximum power output of the turbine is estimated to be around 1330 W with an isentropic efficiency of around 25%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.