Abstract

Intrinsic failure events in gated field emitters have been studied. The gate-emitter voltage, typically 140 V during operation, drops to 10-70 V at the onset of the failure. Measurements with a diagnostic probe indicate that plumes of ions and electrons are ejected into vacuum with the ion current typically 10% of the electron current. The arc voltage and the ion-to-electron current ratio are characteristic of a cathodic vacuum arc. For series resistors less than 1 k Omega , the arc is continuous, whereas for series resistors greater than 10 k Omega , the arc is intermittent. >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.