Abstract

Abstract Uranyl peroxide nanoclusters may impact the mobility and partitioning of uranium at contaminated sites and could be used in the isolation of uranium during the reprocessing of nuclear waste. Their behavior in aqueous systems must be better understood to predict the environmental fate of uranyl peroxide nanoclusters and for their use in engineered systems. The aqueous stability of only one uranyl peroxide nanocluster, U60 (K16Li44[UO2(O2)OH]60), has been studied to date [Flynn, S. L., Szymanowski, J. E. S., Gao, Y., Liu, T., Burns, P. C., Fein, J. B.: Experimental measurements of U60 nanocluster stability in aqueous solution. Geochemica et Cosmochimica Acta 156, 94–105 (2015)]. In this study, we measured the aqueous stability of a second uranyl peroxide nanocluster, U24Py (Na30[(UO2)24(O2)24(HP2O7)6(H2P2O7)6]), in batch systems as a function of time, pH, and nanocluster concentration, and then compared the aqueous behavior of U24Py to U60 to determine whether the size and morphology differences result in differences in their aqueous behaviors. Systems containing U24Py nanoclusters took over 30 days to achieve steady-state concentrations of monomeric U, Na, and P, illustrating slower reaction kinetics than parallel U60 systems. Furthermore, U24Py exhibited lower stability in solution than U60, with an average of 72% of the total mass in each nanocluster suspension being associated with the U24Py nanocluster, whereas 97% was associated with the U60 nanocluster in parallel experiments [Flynn, S. L., Szymanowski, J. E. S., Gao, Y., Liu, T., Burns, P. C., Fein, J. B.: Experimental measurements of U60 nanocluster stability in aqueous solution. Geochemica et Cosmochimica Acta 156, 94–105 (2015)]. The measurements from the batch experiments were used to calculate ion activity product (IAP) values for the reaction between the U24Py nanocluster and its constituent monomeric aqueous species. The IAP values, calculated assuming the activity of the U24Py nanocluster is equal to its concentration in solution, exhibit a significantly lower nanocluster concentration dependence than those IAP values calculated assuming an activity of 1 for the nanocluster. The inclusion of a deprotonation reaction for U24Py minimizes the pH dependence of the calculated IAP values. The modeling results suggest that the U24Py nanocluster experiences sequential deprotonation. Taken together, the results indicate that the aqueous behavior of the U24Py nanocluster, like that of U60, is best described as that of an aqueous complex.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.