Abstract

This paper describes a new research facility which experimentally models hot gas ingestion into the wheel-space of an axial turbine stage. Measurements of CO2 gas concentration in the rim-seal region and inside the cavity are used to assess the performance of two generic (though engine-representative) rim-seal geometries in terms of the variation of concentration effectiveness with sealing flow rate. The variation of pressure in the turbine annulus, which governs this externally-induced (EI) ingestion, was obtained from steady pressure measurements downstream of the vanes and near the rim seal upstream of the rotating blades. Although the ingestion through the rim seal is a consequence of an unsteady, three-dimensional flow field and the cause-effect relationship between pressure and the sealing effectiveness is complex, the experimental data is shown to be successfully calculated by simple effectiveness equations developed from a previously published orifice model. The data illustrate that, for similar turbine-stage velocity triangles, the effectiveness can be correlated using a non-dimensional sealing parameter, Φo. In principle, and within the limits of dimensional similitude, these correlations should apply to a geometrically-similar engine at the same operating conditions. Part 2 of this paper describes an experimental investigation of rotationally-induced (RI) ingress, where there is no mainsteam flow and consequently no circumferential variation of external pressure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call