Abstract

Traditionally, matched-field processing (MFP) has been used to localize low-frequency sources (e.g., <300 Hz) from their acoustic signals received on long vertical arrays. However, some sources emit acoustic signals of much higher frequency. Applying MFP to signals in the mid-frequency range (e.g., 1-4 kHz) is a very challenging problem because MFP's sensitivity to environmental parameter mismatch becomes more severe with increasing frequency. Robust MFP techniques are required to process signals in the mid-frequency range. As a practical issue, short vertical arrays are more convenient to work with than are long vertical arrays; they are easier to deploy and are less prone to large amounts of deformation. However, short vertical arrays undersample the water column, which can result in severely degraded MFP performance. In this paper, we present experimental data results for this nonconventional paradigm. Using the environmentally robust broad-band L/sub /spl infin//-norm estimator, MFP results are given using shallow-water experimental data. This data consisted of broad-band signals in the 3-4-kHz band collected on an eight-element 2.13-m vertical array. These results serve to demonstrate that good localization performance can be attained for this difficult problem. Guidelines on the appropriate use of ray and normal-mode propagation models are also presented.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call