Abstract
A field test of a complicated statically indeterminate floor system on a historic steel truss bridge has been conducted to obtain a more accurate load rating of the structure than possible using calculated predic tions of wheel load distributions. The empirically determined wheel load distributions resulted in the identifi cation of the floor system, particularly the transverse floor beams, as the element governing the load rating of the structure. Favorable lateral distribution of wheel loads among the stringers by a glued laminated treated timber deck was noted. The experimental determination of wheel load distributions has provided an inexpensive means of intelligently allocating limited county resources for the maintenance and rehabilitation of an inventory of aging bridges.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.