Abstract

This paper describes the experimental investigations conducted on a closed loop pulsating heat pipe (CLPHP) for assessing the thermal performance. The pulsating heat pipe has a single closed loop made of copper. The working fluids used are water and titanium dioxide nanofluids with varying concentrations of TiO2 nanoparticles (1.5% and 1%) on weight basis. The TiO2 particles are mixed in water to form a stable suspension using a sonicator. The heat input is varied between 40 W and 100 W in steps of 20 W. All experiments are conducted in the bottom heating mode (evaporator at the top) in the vertical and horizontal orientations. The parameters considered for evaluating the thermal performance are the temperature difference between evaporator and condenser, thermal resistance, heat transfer coefficient, and thermal conductivity. The results of the investigation reveal that the vertical orientation and increase in nanoparticle concentration favors better heat transfer performance of the single closed loop pulsating heat pipe.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.