Abstract

ABSTRACT The design and operation of conventional power plant components is affected by load changes, with the balancing of renewable energy generation leading to an increase in warm and hot starts. Essential parts of these power plant components are flanges e.g. connecting pipes and turbine housings. While being structural rather simple, many influences affect the functionality of these flanges, like the high-temperature behaviour of the bolt material or the temperature distribution in the components. This paper presents parts of a recently finished research project on different influences on the relaxation behaviour of flanges. To investigate the influence of the bolt material, tests were carried out on a model of an IP turbine flange using martensitic X12CrMoWVNbN10-1-1 and nickel-based Ni80A bolts. Each tests included 2000 h of steady state and 3000 h of transient load with a retightening of the bolts after 1500 h. Exemplary relaxation tests on the X12 material provide additional information towards the observed behaviour in the flange tests.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call