Abstract
The current paper presents experimental clocking investigations of the flow field in midspan in a high-pressure transonic turbine with a downstream vane row (1.5 stage machine). Laser-Doppler-velocimetry measurements were carried out in order to record rotor phase resolved velocity, flow angle, and turbulence distributions upstream and downstream of the second vane row at several different vane-vane positions. Additionally, a fast-response aerodynamic pressure probe was used to get the total pressure distribution downstream of the second vane row for the same positions. Altogether, the measurements were performed for ten different first vane to second vane positions (clocking positions) for measurements downstream of the second vane row and two different clocking positions for measurements upstream of the second vane row. The paper shows that different clocking positions have a significant influence on the flow field downstream of the second vane row. Furthermore, different measurement lines upstream of the second vane row indicate that clocking has nearly no influence on the flow field close to the rotor exit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.