Abstract

Static load tests are conducted for two outer-plated steel-concrete continuous composite beams. Performance of the tested beams, including the load-deflection curve,load-strain curve,load-moment curve, plastic-hinge region and the crack of concrete flange of specimens, is analyzed. The test results indicate that effective cooperation can be achieved by the shear connector between the concrete part and the outer-plated steel beam; the composite beams have good overall performance. The concrete filling inside the U-shaped steel beam enhances the global and local stability of the outer-plated steel beam. At the bearing capacity limit state, the plastic strain on sections of both the negative and positive maximum moment develops fully so that ideal plastic hinges are formed relatively. At the serviceability limit state, the deformation and the crack width of continuous composite beams can be controlled effectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.