Abstract
The primary surface heat exchanger (PSHE) is a kind of small size, light weight, high integration heat exchanger. The characteristics of the complex internal structure, complex flow pattern and the flow interaction have a great influence on the heat transfer of the air-air primary surface heat exchanger. Five cross-corrugated air-air primary surface heat exchangers with different core configurations are designed and fabricated applying additive manufacturing technology. The cross angle θ of upper and lower corrugated plates is 0°, 15°, 30°, 45°, respectively. An experimental investigation on the flow and heat transfer performance is carried out. The comparison of test results of overall heat transfer coefficient and the pressure drop for different primary heat exchangers is presented. The test results show that the pressure drop is significantly increased with the cross angle increasing, and the heat transfer performance does not show the linear increasing with the cross angle increasing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.