Abstract
Despite the fact that a supersonic cooling gas film can efficiently insulate aerodynamic heating, its interaction with the mainstream generates a sophisticated flow structure which may cause significant aero-optical ramifications. This study aims to analyze the fluid structure and wavefront distortion of supersonic gas film when subjected to varying nozzle pressure ratios (NPR) by employing two distinct cooling refrigerants, namely C O 2 and air. Within the NPR range of 0 to 2, a linear relationship exists between the wavefront distortion of both C O 2 and air films, while the C O 2 film exhibits higher wavefront distortion than the air. Additionally, the influence of condensation on the discrepancies in aero-optical effects of the two refrigerants is discussed.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.