Abstract

Jacketing is less effective to large square/rectangular RC columns due to the inability of the rectangular-shaped jacket in restraining the dilation of concrete in the middle of a straight side. A new retrofit method is proposed in this work by fiber reinforcing the surface concrete in the middle of a straight side. Fiber reinforcing is achieved by inserting small fiber-reinforced polymer (FRP) bars into the concrete in the plastic hinge zone. The inserted FRP bars act as horizontal reinforcement to increase the ductility of the concrete in a similar way as that in normal fiber-reinforced concrete. When this fiber reinforcing technique is combined with the conventional jacketing, the concrete in all parts of a cross section may be effectively confined. In this work, experimental tests were undertaken to investigate the effectiveness of this new retrofit technique. Six half-scaled columns were tested and the test results demonstrated the effectiveness of the method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.