Abstract

The paper presents the results of an experimental investigation on a multistage centrifugal blower, during rotating stall. The test plant allows to change the turbomachine characteristics; in this research the blower has been tested in two different configurations: two-stage and four-stage, with vaneless diffusers. The unsteady flow field inside the blower has been measured by means of hot-wire anemometers. Three single hot-wire probes have been utilised to measure the development of the rotating stall, while a crossed hot-wire probe has been utilised to obtain the instantaneous flow field behind the impellers. The measurements have been done at different flow rate values, including stall inception.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call