Abstract

This research represents an experimental investigation on the operating limitation of an oscillating heat pipe (OHP). The OHP has six turns and three sections: evaporator, condenser and adiabatic sections with lengths of 40 mm, 64 mm and 51 mm, respectively. Water or a mixture of water and alumina (Al2O3) making up a nanofluid served as the working fluid. Filling ratios ranging from 30% to 70%, and tilt angles (orientation) ranging from 0° to 90° were studied. The experimental results showed (1) the water/Al2O3 nanofluid can enhance the OHP heat transfer performance, i.e., the highest input power (operating limitation) increased when the OHP was charged with water/Al2O3 nanofluid; (2) the operating limitation increased as the filling ratio increased from 30% to 70%, but the optimum filling ratio of the OHP is 30% or 50% when the working power is lower or higher; and (3) the thermal resistance of the OHP decreased as the tilt angle increased, and the operating limitation increased as the tilt angle increased.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.