Abstract

Average and local convective heat transfer coefficients of nitrogen are measured experimentally in an electrically heated circular tube for a range of Reynolds number from 1.08 × 104 to 3.60 × 104, and wall-to-bulk temperature ratio from 1.01 to 1.77. The exit Mach number is up to 0.17, and the heat flux is up to 46 kW·m−2. The molybdenum test section has a 62 diameters heated section with an inside diameter of 5 mm and a 30 diameters entrance section to ensure the fully-developed flow. Uncertainty of Nusselt number is less than 1.6 % in this study. The results indicate that the average heat transfer correlations evaluated by both the bulk and the modified film Reynolds numbers agree well with the experimental data. The local heat transfer results based on bulk properties are compared with previous empirical correlations. New prediction correlations are recommended which are significantly affected by the property variation and heated length. The comparison between the proposed correlations and experimental points shows that 88 % of experimental data fall into an error of 10 %, and almost all data are within an error of 20 %.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.