ABSTRACTHeat transfer area per unit volume (m2/m3) of heat exchangers decides the size of the heat exchangers, over the period of years heat exchangers have undergone numerous development in this aspect. One such attractive design is plate heat exchanger which is very compact and has high thermal effectiveness, whereas the flow nature of fluid through this type of heat exchangers is complex. The most common type of plate heat exchanger is chevron type which suffers from large pressure drop (Δp) at higher heat transfer rates, to overcome this problem bubble finned heat exchangers are designed. In this paper the performance of bubble finned heat exchanger is studied with single phase fluid flow condition. The comparative study of finned and no fin configuration shows that the former has 1.8 times higher rate of heat transfer at lower value of Reynold’s number, further the flow remains laminar hence the Δp is minimum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.