Abstract

The overall seismic performance of steel plate shear walls, including unstiffened SPSW, cross-stiffened SPSW, and SPSW with opening, SPSW with slits and holes, under low cyclic loading were tested. Contrastive analyze their hysteretic curve, loading capacity, lateral stiffness, ductility and energy dissipation coefficient. Results indicate that the unstiffened SPSW seem to be with high resistance lateral stiffness and carrying capacity; however its hysteretic curve show pinch effect obviously. When cross-stiffener was set on unstiffened SPSW, the resistance lateral stiffness and loading capacity can be significantly improved. However, the pinch effect of hysteretic curve does not distinctly change. The resistance lateral stiffness and loading capacity of SPSW with holes and slits is lower, however hysteretic curve is full. In addition, the energy dissipation capacity and the phenomenon which the thin steel plate shear wall shows the zero stiffness even negative stiffness at the point of zero displacement under cyclic loading are dramatically improved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.