Abstract

It is well known that aluminum and water is not compatible in a high temperature environment. Generally, water cannot be used as working fluid in a heat pipe fabricated with aluminum. In the current research, the inner surface of an aluminum oscillating heat pipe (OHP) was modified by chemical chrome plating. A chrome coating was formed in the inner surface of the OHP. Then, water can serve as the working fluid and the first aluminum-water OHP was fabricated successfully. The effects of the heat input and the operating temperature on the heat transfer performance of the aluminum-water OHP was tested. The experimental results show that (1) the aluminum-water OHP can operate for a long time with good heat transfer performance, which shows the effectiveness of the chemical chrome plating surface treatment method for the aluminum-water OHP. (2) The thermal resistance of the aluminum-water OHP decreases with the heat power increases. (3) The operating temperature affects the heat transfer performance of the aluminum-water OHP. And the higher operating temperature of cooling water, the lower thermal resistance of the OHP occurs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.