Abstract

This paper presents an experimental investigation of variation tendency of heat transfer coefficient, log-mean temperature difference and differential pressure of pure R123 and 20 nm Al2O3-R123 nanorefrigerants with four various volume concentrations, 0.03%, 0.13%, 0.18%, 0.23% flowing inside the evaporator of organic Rankine cycle system under the conditions of various heat source temperatures and flow rates. Heat source temperatures are in the range of 50–90 °C at an interval of 10 °C, and heat source flow rates are 0.7 m3/h, 1.3 m3/h and 1.8 m3/h. Results show an increment of heat transfer coefficient along flowing direction for both pure R123 and four Al2O3-R123 nanorefrigerants with the increment of heat source temperature and flow rate, and that of four nanorefrigerants are higher than that of pure R123. There is no optimum value of heat transfer coefficient when operation condition is changed for the loading carrying capacity increasing with the increasing intensity of operation condition. Meanwhile, suspending nanoparticles and increasing heat source temperature can change the variation tendency of heat transfer coefficient along flowing direction except pure R123 and 0.18 vol% nanorefrigerant. In addition, 0.13 vol% as a whole is the optimum volume concentration for both log-mean temperature difference and differential pressure.