Abstract

The natural eco-friendly mixture of R744/R290 was investigated to replace R22 in a fully instrumented water-water heat pump test rig. The test results show that the R744/R290 mixture with optimum concentration of 12%/88% (Mopt) is the suitable working medium for heat pump water heaters because of its higher COP and heating capacity than those of R22 under variable conditions as well as the nominal working condition. The heat pump system with Mopt can supply higher temperature hot water and promote compressor lifetime in substitution of R22. The test results also reveal that the heating COPs of heat pump system with Mopt are 4.98–11.00% higher than those of R22 at the heat sink outlet temperature ranging from 45 °C to 65 °C, and the heat sink outlet temperature has obvious effect on the system efficiency but little on the heating capacity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.