Abstract

The experimental study of a 3kW organic Rankine cycle (ORC) system using an open-drive scroll type expander and R245fa has been investigated. The expander is originally hermetic-type refrigerant scroll compressor with built-in volume ratio of 3.24. The effects of pressure drop, degree of superheating and condenser temperature on system overall performance are examined. Moreover, the detailed behavior of pump and expander are explored. The experimental results show that the pressure drop exhibits a relatively higher sensitivity on system performance. The condenser temperature exhibits a negative effect on electrical power, thermal efficiency and system generating efficiency. The maximum expander shaft power, electrical power, thermal efficiency and system generating efficiency are 2.64kW, 1.89kW, 5.92% and 3.93%, respectively. The highest thermal efficiency does not represent the highest expander shaft power.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.