Abstract

The paper presents a wind tunnel experimental investigation of a small-scale building model (1:30). The main objective of the study is to determine the influence of the reference wind direction over the ventilation inside the double skin façade (DSF) channel. The analyzed system consists of a building equipped with photovoltaic panels as the exterior glazing of DSF. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The aim is to determine with acceptable probability the velocities that can be reached in the ventilated façade channel during the warm season and to establish a correlation between the external reference velocity magnitude and direction and the velocity field generated inside the channel of the façade. Measurements were carried out for the reference wind speed, total, dynamic and static pressure both in the reference point and inside the façade channel. The results of the investigation highlighted the correlation between the velocity and direction of the reference wind and the dynamics of the air movement inside the double skin façade. The measurements showed that for the analyzed configuration of the double skin façade, there is an optimal wind direction that ensures the best cooling effect to photovoltaic panels. Also, the convective heat transfer coefficients were determined under these conditions. The decrease of the photovoltaic panel’s temperature determines a raise of its efficiency and generated power.

Highlights

  • Q RUGHU WR GHVLJQ WKH ZLQG HIIHFW WKH PHDQ YDOXHV IRU YHORFLW\ DQG GLUHFWLRQ DUH QHFHVVDU\ 7KH HIIHFW RI WKH IOXFWXDWLRQV DUH GHWHUPLQHG XVLQJ SUREDELOLVWLF WKHRULHV DQG VWDWLVWLFDO GLVWULEXWLRQV RI WKH ZLQG YHORFLWLHV DQG SUHVVXUHV 'XULQJ H[SHULPHQWDO DQDO\VLV WKH YDOXHV UHFRUGHG FRQWLQXRXVO\ DQG GLVFRQWLQXRXVO\ DUH XVHG IRU FDOFXODWLQJ WKH PLQXWHV DYHUDJH YDOXHV DQG REWDLQ WKH EDVLF ZLQG YHORFLW\ >@.

  • UDQGRP ZLQG VSHHG DQG SUHVVXUH IOXFWXDWLRQV 7KH SHDN

Read more

Summary

Introduction

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.