Abstract

Marine risers are key equipment in deep-water oil and gas development. They are prone to vortex induced vibration (VIV) in deep water and in strong current environments, and the vibration mechanism becomes more complicated when there is wake interference. Long term VIV causes fatigue damage to the structure. A series of tests were conducted to study the effectiveness of splitter plates in different arrangements in suppressing riser VIV under wake interference conditions. Strain responses in the cross-flow (CF) and in-line (IL) directions were measured and showed a significant reduction in VIV, indicating that the presence of the splitter was effective in suppressing both CF and IL response of the riser. The arrangement of splitter plates plays an important role in VIV suppression, with better suppression effects occurring where L/D = 1.0, 1.25, and 1.5 (where L is the transverse length of the splitter plate and D is the diameter of the riser). The spacing ratio is also important for VIV suppression, but the influence varied for different splitter plate arrangements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.