Abstract

In this paper, a thermal management system of a personal computer power supply unit (PSU) is experimentally investigated. The simultaneous use of a passive cooling system such as PCM with a fan that is an active cooling system can improve performance and increase the lifetime of the PSU. Three cases with different volume fractions of fins have been fabricated. To investigate the effect of the fan on the thermal performance of the PSU, the experiments carried out at a minimum and maximum fan speed. The chosen PCM for this study, CaCl2.6H2O , is an inorganic salt-hydrate. According to the different operating conditions of the PSU, the input heat fluxes to the heat sink are variable. The results show that with simultaneous of fan/PCM, the average reduction in the steady temperature of the PSU circuit at the minimum and the maximum fan speeds are 12.8 (°C) and 12.4 (°C), respectively. The results indicate that increasing the number of fins does not have a favorable effect on the thermal performance of the PSU. On the other hand, using of a passive cooling system like PCM can be effective in reduction the dimensions and energy consumption of the fan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.