Abstract

AbstractThe results of an experimental campaign of three-point bending tests on precast composite beams, named hybrid steel–trussed concrete beams (HSTCBs), are provided. HSTCBs are typically constituted by a precast steel truss embedded in a block of concrete cast in place. Two series of specimens were manufactured, designed such that shear failure would occur, and tested under positive and negative bending moment. The experimental results obtained showed that fragile shear failure occurred in almost all cases, evidencing the crisis of the compressed concrete strut involved in the collapse mechanism. Yielding of the steel members provided ductility to the system, especially in those cases in which the mechanical properties of the concrete were adequate and allowed the failure of the strut to be delayed. Some of the more accredited expressions for prediction of shear resistance available in the literature were used to assess the shear capacity and compared against those experimentally obtained for all spe...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.