Abstract

The saturated vapor pressure of liquid potassium–cesium alloys of five compositions (15.0, 30.0, 50.0, 65.0, and 85.0 at. % Cs) is measured by the U-tube manometer method in the temperature range from 760 to 1289 K. The alloys are prepared by the weighing method at a fairly high purity of starting potassium and cesium (>99.99 wt % for each of the alkali metals). The confidential error of the experimental results is in the range from 1.0 to 1.5%. The approximating equations for the saturated vapor pressure of the investigated K–Cs alloys are derived from the statistical regression analysis of the experimental data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.