Abstract
An experimental investigation was conducted and a test facility constructed to measure the capillary heat transport limit in small triangular grooves, similar to those used in micro heat pipes. Using methanol as the working fluid, the maximum heat transport and unit effective area heat transport were experimentally determined for ten grooved plates with varying groove widths, but identical apex angles. The experimental results indicate that there exists an optimum groove configuration, which maximizes the capillary pumping capacity while minimizing the combined effects of the capillary pumping pressure and the liquid viscous pressure losses. When compared with a previously developed analytical model, the experimental results indicate that the model can be used accurately to predict the heat transport capacity and maximum unit area heat transport when given the physical characteristics of the working fluid and the groove geometry, provided the proper heat flux distribution is known. The results of this investigation will assist in the development of micro heat pipes capable of operating at increased power levels with greater reliability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.