Abstract
One of the worst accidents that may occur in a high-vacuum-multilayer-insulation (HVMLI) cryogenic tank is a sudden, catastrophic loss of insulation vacuum (SCLIV). it is obvious that the different gas leaking into the insulation jacket have some influence on the heat transfer process. However, this problem has not been studied systematically so far. In this paper, a test rig was built up and experiments were conducted on a SCLIV cryogenic tank by using the nitrogen, helium, oxygen, carbon dioxide and air as the leaking medium, respectively. Some important phenomena and heat transfer characteristics in a vacuum-lost HVMLI cryogenic tank have been obtained. The effects of the insulation layer numbers and the type of gases on venting rate and heat flux into the cryogenic liquid have been measured, analyzed and discussed. It indicates that the heat transfer performance of the HVMLI cryogenic tank after SCLIV is strong related to the type of gases leaking into the insulation jacket.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.