Abstract

One of the most commonly utilised maximum power point tracking (MPPT) algorithms for photovoltaic (PV) generators is the incremental conductance (INC) algorithm. Yet, the operating characteristics of this algorithm at high perturbation frequencies, when the system response to MPPT perturbations is never allowed to settle, have not been addressed in the literature. This study characterises system behaviour in this operating mode experimentally for a standalone PV system with a dc motor–pump load. Results show that the INC algorithm operating at a high perturbation rate offers higher energy utilisation efficiency and better system performance despite the resulting non-periodic waveforms of the system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call