Abstract

In this experimental study, performance of counter flow type Ranque-Hilsch vortex tubes (RHVT), with a length to diameter ratio of 10, 15 and 18, were investigated with 2, 4, 6 nozzles. The measure of performance was chosen as the difference between the temperatures of hot output stream and cold output stream. The performances of RHVTs were experimentally tested by making use of velocity and temperature measurements of the input and output streams. It was determined that the difference between the temperatures of these streams, changed between 9 and 56 K. When all the results were assessed, it was concluded that the best performance was obtained when the ratio of vortex tube’s length to the diameter was 15 and the nozzle number was at least four, and the inlet pressure was as high as possible. Desired performance could be obtained by controlling the rate of the hot output stream.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.