Abstract
It has been recognized that the pressure pulsation excited by rotor‐stator interaction in large pumps is strongly influenced by the radial gap between impeller and volute diffusers/tongues and the geometry of impeller blade at exit. This fluid‐structure interaction phenomenon, as manifested by the pressure pulsation, is the main cause of flow‐induced vibrations at the blade‐passing frequency. In the present investigation, the effects of the radial gap and flow rate on pressure fluctuations, vibration, and pump performance are investigated experimentally for two different impeller designs. One impeller has a V‐shaped cut at the blade′s exit, while the second has a straight exit (without the V‐cut). The experimental findings showed that the high vibrations at the blade‐passing frequency are primarily raised by high pressure pulsation due to improper gap design. The existence of V‐cut at blades exit produces lower pressure fluctuations inside the pump while maintaining nearly the same performance. The selection of proper radial gap for a given impeller‐volute combination results in an appreciable reduction in vibration levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.