Abstract

In this paper, the effects of integrated fins on the thermal performance of the concentric tube heat exchanger with a variable flow rate of hot and cold water are discussed. The inner pipe is made of copper pipe of length = 800 mm, OD=30 mm, ID=26 mm, t=2 mm. the integrated fines of the geometry 1.25 mm and 1.5 mm pitch length, 1 mm of the depth of cut are considered in the study. The thermal performance of the heat exchanger with a flow rate of hot and cold fluids ranges from 0.014 kg s- 1 to 0.07 kg s-1 and the effects of parallel and counter flow direction are also discussed in detail. The experimental result confirms that the thermal performance of the concentric tube heat exchanger is more in the case of the tube with integrated fins and counter flow direction with the highest flow rate of water in the pipe and annulus of the heat exchanger.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.