Abstract

The following study analyzes the shear behavior of full-scale slabs without shear reinforcement (the design of slabs used in nuclear buildings) under a concentrated load near a linear support. Experimental tests were conducted to quantify the shear strength and the associated failure modes. We addressed the influence of several variables, such as bottom longitudinal reinforcement, bottom transverse reinforcement, compressive strength, concrete aggregate size, and influence of the slab depth. A series of ten tests on nine full-scale slabs (one slab of 3.2m×2.9m×0.3m; six slabs of 4m×2.6m×0.3m; one slab of 4m×2.6m×0.35m; one slab of 4m×2.6m×0.4m) are presented. Realistic boundary conditions with the slabs supported on all four sides were used. The experiments are firstly used to evaluate the pertinence of Eurocode 2 for the shear design of reinforced concrete slabs without shear reinforcement in comparison with the French approach, and then to make comparisons with the ACI 318-14 code. We also studied the verification of a new proposal for the extension of Eurocode 2 proposed by Lantsoght et al. (2015).