Abstract
AbstractA series of subassembly tests were conducted to investigate the behavior of the self-centering steel plate shear wall (SC-SPSW) system under cyclic loading. The SC-SPSW system utilizes thin steel web plates to provide energy dissipation and the primary strength and stiffness of the system, whereas posttensioned (PT) beam-to-column connections provide recentering capabilities. In this new system, the web plate is intended to yield under cyclic loading, whereas the boundary elements and PT connection elements remain undamaged. The web plate can then be replaced relatively easily following significant inelastic cycles. This experimental program studies the effects of various design parameters on the system and connection response and compares the response with approximate analytical formulas. The experimental results show that the SC-SPSW system has high ductility, high initial stiffness, recentering capabilities, an overall system response as anticipated, and more energy dissipation than expected.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.