Abstract

AbstractIn this work, a hydrogen-fueled dual-mode scramjet combustor was investigated experimentally. Clean and dry air was supplied to the combustor through a Mach 2 nozzle with a total temperature of 800 K and a total pressure of 800 kPa. The high enthalpy air was provided by an electricity resistance heater. Room temperature hydrogen was injected with sonic speed from injector orifices vertically, and downstream the injector a tandem cavity flame holder was mounted. Except wall pressure profiles, velocity and temperature profiles in and at exit of the combustor were also measured using hydroxyl tagging velocimetry (HTV) and tunable diode laser absorption spectroscopy (TDLAS), respectively. Results showed that combustion occurred mainly at the bottom side of the combustor. And there were also an extreme disparity of the velocity and temperature profiles along the