Abstract

An experimental investigation of operational parameters, including liquid/gas ratio (L/G), inlet nitric oxide (NO) concentration, reaction temperature, and pH value of absorbing agent, on NO removal efficiency with hexamminecobalt(II) solution scrubbing was conducted on a pilot-scale facility to search optimal operation conditions. The experimental results show that NO removal efficiency increased with the pH value of hexamminecobalt solution, while the improving rate dropped gradually. When the reaction temperature increased, the NO removal efficiency increased first and then decreased. At the same time, NO removal efficiency increased with the increasing of L/G and hexamminecobalt concentration, while the removal efficiency did not change much at low NO concentration. The pH of 10.4 and L/G of 16 L/m3 were close to the optimal operation conditions, and the scrubbing temperature fell within a reasonable operation temperature. The experimental results can be used as a reference for the design and operation of scaled-up industrial devices.