Abstract

An investigation into the limiting oxygen concentration (LOC) of fifteen combustible dusts and methane, ethanol and isopropanol hybrid mixtures in the standard 20 L explosion chamber was performed. Three ignition energies (10 J, 2 kJ and 10 kJ) were used. The results show that a 10 J electrical spark ignition leads to significantly higher limiting oxygen concentration values than either 2 kJ or 10 kJ pyrotechnic igniters. This could be due to the “overdriving” effect of the chemical igniters, which produce a hot flame that virtually covers the entire explosion chamber during combustion. With respect to hybrid mixture investigation, the 20 L sphere was modified to allow the input of methane gas and flammable solvents. The limiting oxygen concentrations of the hybrid mixtures were found to be considerably lower than those of dust air mixtures when the relatively weaker spark igniter was used. There was no significant change in limiting oxygen concentration when the higher energy chemical igniters were used.