Abstract

An increase in global warming potential and other environmental concerns are demanding new environmentally friendly refrigerants. For effective performance of refrigeration and air conditioning system condenser design play a vital role. Experiments were conducted to study the condensation of R1234yf refrigerant inside a copper tube of 8.4 mm in diameter and 750 mm in length. The heat transfer coefficients of refrigerant were calculated against mass flux varying from 150–300 kg/m2 s, quality of refrigerant 0.3 to 0.8, and saturated temperature 30 and 500 C. The experimental heat transfer coefficients were compared to the heat transfer coefficients by the recent MM Sha correlation. The experimental results are in good agreement with an absolute mean deviation of nearly 20% with the MM Sha heat transfer coefficient.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.