Abstract

Small refrigerative dehumidifiers, which are commonly used in New Zealand to reduce household moisture, typically operate in relatively cool environments, outside their optimum performance envelope. This study investigates the potential for improving the low-temperature dehumidification capacity of a domestic dehumidifier using an evaporator economiser, with particular emphasis on the limitations caused by evaporator frosting. The paper reports performance measurements on a modified domestic dehumidifier which can be operated either geared with an evaporator economiser, or ungeared. An empirical heat pump model, which was calibrated using the ungeared performance data, was also used to compare the two modes. The measured results show a clear improvement in the dehumidification capacity in the geared mode at the higher temperatures tested. The performance improvement in the lower temperature tests was less than that predicted by the model due to increased evaporator frosting under gearing and to limitations in the economiser model relating to latent cooling.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.