The present study is the second half of a piece of work carried out in collaboration with SNECMA. It investigates shaped hole film cooling, numerically and experimentally. The aim of this paper is the experimental analysis of shaped hole film cooling on a large scale turbine blade (1.4 m chord). The test section is a large scale turbine inlet guide vane cascade. The test airfoil is equipped with a row of nine 50 degrees sloped shaped holes. They are located on the suction side at 20% of the curvilinear length of the blade from the stagnation point. The inlet film cooling hole diameter is 12 mm. The jet flow is heated to 55 degrees C above the crossflow temperature. Velocity and temperature field measurements have been done to obtain mean and fluctuating values. The results are compared to those obtained by Béral on the same experimental apparatus and in the same test conditions, for a row of cylindrical holes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.