Abstract

Vacuum interrupter is widely used in the medium-voltage power system. Controlling the arc by the magnetic field is an effective method to improve the breaking capacity. The transverse magnetic field (TMF) forces the constricted arc to rotate to reduce local overheating. In this paper, three kinds of TMF contacts, which are Swastika-type contact, cup-shaped contact, and double-TMF contact that combines Swastika-type and cup-shaped contacts coaxially, are investigated in a demountable vacuum chamber with a high-speed camera. The arc voltage and current are also recorded. The experiments were conducted with circuit currents from 5 to 20 kA (root mean square) with a frequency of 50 Hz. There are four current levels in the experiment, which are 5, 10, 15, and 20 kA, and at least three tests are taken for each current level. The results showed that under low current (I = 10 kA), the arc of the three TMF contacts did not rotate. Under high current (I = 20 kA), it was observed that the arc of Swastika-type and double-TMF contacts rotated in the gap. The arc speed of double-TMF contacts is higher than that of Swastika-type contacts. The cup-shaped contacts have the highest arc voltage and noise among the three TMF contacts. The Swastika-type contacts were eroded most seriously. The simulation results show the force distribution of the arc on different locations. The resultant force makes the arc rotate counterclockwise.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.