Abstract

Abstract This paper presents the results of comprehensive testing to characterize the effect of several different surface treatments on shear and tensile bond strength between 7075-T6 aluminum and two epoxy systems: EPON 815/V40 and EPON 828/Z. A rod pull-out test was used to determine interfacial shear strength, modeled after similar tests on reinforced concrete. The tensile bond strength was characterized using a tension test fixture designed in this study. Overall, the interfacial shear strengths were higher than the tension strengths. Surface knurling gave the highest interfacial shear strength, representing a 72% increase over untreated specimens. Phosphoric acid anodization (PAA) was also quite effective in shear. In tension, the highest strength was obtained from specimens treated with the PAA process along with a silane coupling agent. These specimens showed an increase in interfacial tensile strength by a factor of 5.6.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.